(Mobilecool outdoor) Telecommunication Base Station Special Air Conditioner(Shelter cooling)
Model:3E1C0~15E1C4
Temperature control range:-15°Cto 50°C
Air flow:800~3500 m3/h
1.Application
Telecommunication base station
Switching room
Battery station
Power distribution station
Railway signal base station
2. Unit identification
MOBILECOOL-OUTDOOR | . | OUDL | 71013… | E1 E2 | C1 C2 C3 | R407 R410 | XXX |
1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 |
1 | Product series name: |
MOBILECOOL-OUTDOOR:Outdoor installed packaged air conditioner with fresh air free cooling, can be abbreviated as “M-OD”. | |
2 | Separator: “.” |
3 | Air supply mode O: Air delivery at the unit front, high level U: Air delivery at the unit bottom DL: Air delivery at the unit front, low level |
4 | Unit nominal cooling capacity by kW |
5 | Compressor type & number: “E1” means the unit is equipped with 1 compressor; “E2” means the unit is equipped with 2 compressors |
6 | Cabinet size code |
7 | Refrigerant type: R407=R407c refrigerant R410=R410a refrigerant |
8 | Special design code |
3.Advantages
Good structure design The unit is designed to be installed universally. It is not needed to make a distinction between left and right hand installation when it is to be adjacent installed at the end of shelter base station. |
The main components such as: compressor, fan, motor, damper and other related components can be accessed in front of the unit and can be field replaced without removing the units when installed side-by-side on the same end of shelter. |
Dual cooling source( MOBILECOOL-SPLIT excluded) Each unit is equipped with both mechanical cooling system and free cooling system as standard. The fresh air free cooling is designed to be the primary source of cooling. |
Anti corrosion All unit framework is provided with corrosion protection treatment. The treatment is sufficient to provide a protection for 15 years life cycle for inland installation. If necessary, the treatment for sea air environment can be supplied as optional. |
High sensible heat ratio The Sensible heat ratio of all the units are high than 0.9 |
Wide working range The unit can work at minimum -15°C(-22°F), maximum 52°C(125.6°F) ambient temperature continuously and reliably. |
High capacity air filter When the pressure drop of the filter reached 250Pa end resistance, the unit air flow will not be less than 90% of air flow at standard condition. |
High torque and low leakage air damper The air filter is equipped with a high torque and low leakage air damper. The time for opening and closing the damper is less than 90 seconds. The Air Leakage across damper is less than 5% by volume of the air normally passing through the unit when a reverse pressure of 125 Pa is applied to the damper |
Easy maintenance There is necessary clearance between components; every component can be easily dismantled from the unit. The weight of all the panels is controlled less than 10 kg. |
Strong structure The unit passed a transportation test to confirm the structure is strong enough to be able to transport on low grade road. |
Smaller dimensions The unit has a smaller dimension because of compact optimized structure design. Its volume is the smallest among the products with similar performance of other suppliers. |
Clear label A lot of labels according to relative standard are applied for the unit inside or outside, including: indicating labels, safety labels, running label, maintenance label etc. |
Fully automatic control The unit is equipped with a full automatic control system, all the control and protection and alarm is automatic with auto restart. |
Auto changeover of working mode The unit automatically selects the working mode: mechanic cooling or free cooling according to the temperature of indoor side and outdoor side. In the event of either electrical or mechanical failure affecting the refrigeration system, the unit will be capable of automatic reversion to the fresh air cooling mode. |
Random restart when power recovered After a power failure, when the power is recovered, the unit will restarts automatically with a random time delay between 1 to 60 seconds to avoid many equipments started at the same time. |
Automatic self-diagnosis All the components connected to microprocessor are continuously tested. In case of malfunction, the failure is shown on the display with information accordingly. |
The Attend Mode function When service people is working in base station, he can simply press 2 buttons on the controller interface, then the control temperature of the air conditioner will be set as 22°C(71.6°F) (settable) automatically. Half an hour later (settable), the control temperature of air conditioner will be returned to original set point. |
4 levels password protection There are 4 levels password protection for the control system |
Voltage protection There is a voltage relay for protection. When the supply voltage is out of permitted range, the unit will be stopped. For 3 phase unit, if there is phase unbalance or phase absence, the unit will also be stopped for protection. |
2 types alarm There are a lot of alarms for the complete protection to the unit |
Night storage cooling The customer can enable or disable the control function according to actual situation. If this function is enabled, the control temperature will be reduced when it is running on night time between 18-00hrs and 06-00hrs. So, some cooling capacity can be stored by the low cooling air at night and then be used for day running. |
Humidity limitation The control function can be enabled or disabled on site. If it is enabled, and the humidity of outside is high than 90%, free cooling will be turned off in order to avoid outside humid air introduced to inside of base station. |
Automatic maintenance test A maintenance test facility is provided to enable an engineer to press/select one button that will activate a self-test routine. The self-test routine will check for the satisfactory operation of the fresh air damper and the compressor refrigerant circuits. |
Running data logging The controller has a memory of 1M for data logging. If the interval of data logging is less than 5 minutes, the controller can store at least 48 hours working data |
Data output A facility for a connection RS485 (Optional) of a computer lead to enable automatic downloading of logs and parameters into either a CSV file or Excel file to allow for automatic data entry into database. |
Free cooling |
Ifthe temperature of outdoor temperature is 2 °C or more lower than indoor temperature, the free cooling will be started up to introduce the outdoor air and the indoor air is displace to outdoor, so the indoor air is cooled by outdoor air. |
High efficiency EC fan (Optional) |
EC fan is featured with high efficiency, wide speed adjustment range, low noise, light weight and over 10 years running time continuously. |
High efficiency compressor |
Compressor is the key component of cooling. We use high efficiency compressor to have a basic energy saving. |
Displacement air supply |
Cold air is supplied at low level. The air gets heat at low level and is displaced to high level. So, the inlet air of air conditioner can be higher and the air temperature difference between inlet and outlet can be bigger, which means the air flow rate of the unit can be reduced and at the same time, the energy consumption of supply fan is reduced. Comparing with up flow air distribution, displacement air distribution can save 2~5% energy. |
(Mobilecool outdoor) Telecommunication Base Station Special Air Conditioner(Shelter cooling)